All scadenza except for the trajectories in Figs

All scadenza except for the trajectories in Figs

1a,e–g and 2e,f were acquired on per Refeyn OneMP mass photometer with per 10.8 ? 2.9 ?m 2 (128 ? 35 pixels) field of view. The microscope used sicuro acquire the tempo per Figs. 1a,e–g and 2e,f was custom-built with per 9.4 ? 6.2 ?m 2 field of view (138 ? 88 pixels with per binned pixel size of 70.3 nm) and is similar sicuro that described previously 18 . The custom-built setup is illustrated per Supplementary Fig. 15 and the differences sicuro the setup used mediante our previous work are highlighted mediante the figure caption.

Dynamic mass photometry

Preciso acquire dynamic mass photometry movies, the SLBs were placed on the sample stage puro optimize the focus of the microscope. After locking the focus of the microscope, WT or ?PRD was added onesto the SLB by replacing 3–6 ?l buffer from the silicone gasket with 3–6 ?l (total libro, 60 ?l) 200 nM WT or ?PRD (per reaction buffer) solution and missaggio well with verso micropipette onesto achieve verso final concentration of 10–20 nM. Scadenza acquisition was started ?10 s after the additif of protein. Images were collected at 994 Hz and saved after the binning of pixels into blocks of 4 ? 4 and the binning of frames into groups of 3, resulting durante an effective frame rate of 331 Hz and verso final pixel size of 84.4 nm (for the datazione used sopra Extended Data Figs. 2, 3, 8 and Supplementary Figs. 3 and 13 the pixel size was 77.4 nm).

5–10 s) once every minute (20,000 frames) sicuro readjust the microscope focus puro account for drift over time before resuming acquisition. This resulted in sets of multiple 1 min movies for each SLB and sample combination. For experiments on the effect of GTP, 3–4 movies of WT (10–20 nM) were recorded as described above, after which image acquisition was briefly paused and 1.2 ?l GTP (50 mM) was added (total gasket registro, 60 ?l), followed by mixage to obtain verso final concentration of

1 mM before the resumption of acquisition. For the datazione shown con Extended Momento Fig. 8, GTP or GMPPNP was added at the beginning of the measurement together with WT (20 nM), that is, each sample condition was measured on a separate SLB. The number of replicate measurements is indicated per figure captions and corresponds esatto the number of sets of movies that were taken for each sample. We used the same purified batch of WT and ?PRD for all scadenza collected on the OneMP setup.

Background subtraction

Dynamic mass photometry movies were processed by treating each frame with a sliding median retroterra subtraction algorithm. Durante brief, each frame was divided by its local median, that is, the median of per pre-defined frame interval (here, 201 frames or 607 ms) centered around the frame of interest, puro calculate the background-subtracted frames, F:

where xi is the current raw frame and Xi?100:i+100 represents the median pixel values of raw frames, from i ? 100 up to (and mobili gaydar including) i + 100. Each background-subtracted frame was then additionally treated with a two-dimensional (2D)-median noise filter to remove any large dynamic background sources (for example, fluctuations in illumination, if present). The window size of 201 frames for the sliding median algorithm was chosen because it was the smallest window size that did not detrimentally affect particle contrast or contrast precision (Extended Data Fig. 10). For smaller window sizes, particle contrast values and contrast precision decreased significantly, especially for larger particles that were less mobile, while larger window sizes increased processing times without an additional increase in sensitivity or performance. We anticipate that for slower moving particles (D < 0.3>

Schreibe einen Kommentar

Deine E-Mail-Adresse wird nicht veröffentlicht. Erforderliche Felder sind mit * markiert